We require a vacuum chamber with pumps and thermal plate capable of reaching 10-6 mbar pressure, or below, with a thermal control system for the internal volume that allows fixed and cycling temperatures between -35 and +100 degrees C.
The internal volume of the chamber should accommodate a test unit of minimum size 350mm x 100mm x 100mm (i.e. the internal volume should be at minimum 500mm x 300mm x 300mm), however larger internal volume is desirable.
The chamber should have at least one feed through for power and data communications to the device inside such that tests of electronics can be controlled from outside of the chamber.
The system should include any temperature and pressure sensors required for accurate operation.
The system should not require cryogenic cooling or any form of liquid nitrogen supply, and be suitable for installation in a laboratory setting on the second floor.
The system should include all pumping, cooling, command and control devices required for complete functionality.
What the notice asks for
We require a vacuum chamber with pumps
We require a vacuum chamber with pumps and thermal plate capable of reaching 10-6 mbar pressure, or below, with a thermal control system for the internal volume that allows fixed and cycling temperatures between -35 and +100 degrees C.
The internal volume of the chamber should
The internal volume of the chamber should accommodate a test unit of minimum size 350mm x 100mm x 100mm (i.e. the internal volume should be at minimum 500mm x 300mm x 300mm), however larger internal volume is desirable.
The chamber should have at least one
The chamber should have at least one feed through for power and data communications to the device inside such that tests of electronics can be controlled from outside of the chamber.
The system should include any temperature
The system should include any temperature and pressure sensors required for accurate operation.
The system should not require cryogenic cooling
The system should not require cryogenic cooling or any form of liquid nitrogen supply, and be suitable for installation in a laboratory setting on the second floor.
Sentences from the notice that state an obligation, surfaced automatically and shown in the order they appear. Not an exhaustive list — always confirm against the tender documents.
Make the case to bid
Reveal who to approach at Northumbria University at Newcastle, and generate a go-to-market strategy from their news, accounts and people.
Free to start. Named contacts come from published notices; the strategy is generated from the buyer’s news, accounts and people.
- OCID
- d31788e3-5e13-4042-8595-0f1e44c244cf
- Stage
- contract · Contract
- Source
- Contracts Finder
- Buyer ref
- BIP674923839
Contains public sector information licensed under the Open Government Licence v3.0. Source data © Crown copyright.
Who wins this kind of work
The suppliers and buyers around this opportunity — drawn from official award data. Drag to orbit; click a node to explore.
Top suppliers & buyers in Medical Equipment & Pharmaceuticals
Northumbria University at Newcastle’s tender network