OO- Works - Provan Gas Holder Refurbishment - 0326
The procurement contact named on the official notice.
The submission route named on the official notice.
There is a requirement to carry out some repairs to the two frames of the column guided gasholders located off Blochairn Road in Glasgow.
The gasholder frames at Provan are nationally listed, grade B.
A detailed structural survey and a Hardness test of sample members has been undertaken on both gasholder frames.
The purpose of carrying out the survey and tests was to inform SGN of the structural condition of the gasholder frames but also determine the possible repair and refurbishment strategy for the gasholder frames.
The survey has established the structural performance requirements of the individual elements of the gas holder frame.
The survey has identified defects which have been categorised as A required to be remediated within 1 year B require to be remediated within 2 years.
There are 9 identified A defects on holder 1 and 15 on holder 2.
The A listed defects have not included staircases, hand-rails and walkways which have been assumed they would be removed as part of the early phase of works, subject to Local Authority and/or Historic Environment Scotland (HES) approval.
The A listed have been classified as showing severe defects such as large amounts of holing, thinning into deterioration, significant section loss (5.1% to 20%).
The B listed items have been classified as moderate defects such as minor to moderate amount of holing, thinning/warping/major pitting, small section loss (2.1% to 5.1%).
To note, it is likely that any scaffolding or similar structure provided would take lateral and vertical support from the gasholder frame, and as such the wind loading exerted on the frame by the scaffold enclosures is likely to become a critical load case in terms of the structural assessment.
The structural assessment has identified the likely restrictions that may be placed on the extent of the gasholder that can be enclosed at any one time.
What the supplier must deliver
The survey has identified defects which have
The survey has identified defects which have been categorised as A required to be remediated within 1 year B require to be remediated within 2 years.
To note, it is likely that any
To note, it is likely that any scaffolding or similar structure provided would take lateral and vertical support from the gasholder frame, and as such the wind loading exerted on the frame by the scaffold enclosures is likely to become a critical load case in terms of the structural assessment.
Derived from the notice text — always confirm against the original documents.
Make the case to bid
Reveal who to approach at SCOTIA GAS NETWORKS LIMITED, and generate a go-to-market strategy from their news, accounts and people.
The full intelligence dossier
Our agent reads SCOTIA GAS NETWORKS LIMITED’s accounts, hunts live signals, finds the people who decide — and hands you a bid strategy plus a go-to-market influence plan, including what your team should post this week. You approve every paid step.
Ask me about this tender, the buyer, who wins their work, or whether you should bid.
- OCID
- ocds-h6vhtk-042db4
- Stage
- tender · Open
- Source
- Find a Tender
- Buyer ref
- 001520-2024
Contains public sector information licensed under the Open Government Licence v3.0. Source data © Crown copyright.
Who wins this kind of work
The suppliers and buyers around this opportunity — drawn from official award data. Drag to orbit; click a node to explore.
Top suppliers & buyers in Construction
SCOTIA GAS NETWORKS LIMITED’s tender network
Assembling the network…