RFP QuestBeta
ClosedStage · tender

Health and Safety Executive

Gaseous Hydrogen Pressure Reduction Station

Laboratory EquipmentCPV 38800000
Value£35k
Deadline13 Mar 2026
Published12 Feb 2026
RegionNationwide
Timeline
Published 12 Feb 2026ClosedCloses 13 Mar 2026
Who to contact
tenders@hse.gov.uk

The procurement contact named on the official notice.

How to submit
Open the submissions portal

All tender documents are available via the HSE In-Tend supplier e-procurement portal. All responses and requests for clarification must be submitted via the portal. Registration is free of charge and can be completed via the following link: https://in-tendhost.co.uk/hse

The submission route named on the official notice.

Contract value in context
£35ktotal contract value
median £70k
this tender£0£588k

This sits in the lower-middle of the Laboratory & Precision Equipment band — a mid-scale opportunity. Based on 9,869 valued Laboratory & Precision Equipment tenders in our corpus.

Match for your company
Sign up free to see how well this tender matches your company — the score, the signals that align, and where the gaps are.
The brief

HSE require a gaseous hydrogen pressure reduction station for use during a research test programme.

The PRS will be connected to a bulk hydrogen supply up to 500 barg.

The PRS should be able to control a flow of gaseous hydrogen at a set flow rate within the range 20 - 400 g/s.

The system should respond to a setpoint which is determined from an analogue signal sent to the pressure regulator.

If a dome regulator is used, HSE will provide and install a nitrogen supply to the regulator.

The PRS will be connected to a vent stack and pressure relief system, which will be provided and installed by HSE before the system is used for experiments.

The PRS should be instrumented with pressure and temperature upstream and downstream of the regulation, and a mass flow meter.

These sensors should have analogue outputs (ideally 4-20 mA signals) suitable for connection to a separate data logging system.

Please give details of the accuracy and calibration of instrumentation.

Instrumentation should be ATEX rated and suitable for hydrogen.

Inlet: Hydrogen @ up to 500 barg, -10 to 25 °C Outlet: Hydrogen @ up to 100 barg, up to 400 g/s Pipework: 1" ID stainless 316L steel, 1 connection suitable for 500 barg to tube trailer, 1" Class 900 flange on the downstream connection.

Upstream of the regulator, the system should have a maximum allowable working pressure of at least 700 barg.

Downstream of the regulator, the system should have a maximum allowable working pressure of 150 barg and a bursting disc set for this pressure.

The PRS should also include an upstream isolation valve with a maximum allowable working pressure of at least 700 barg.

This valve should be pneumatically actuated and include an ex-d position indication.

Instrumentation: Pressure and temperature upstream and downstream of the regulator, mass flow meter after the regulator.

Instrumentation should be ATEX rated, suitable for hydrogen.

4-20 mA output preferred.

Please give details of the accuracy of instrumentation.

Skid: The pressure reduction system should be mounted on a skid with ports suitable for transport with a forklift.

The skid must have attachment points for bolting to ground and points for earthing the system.

A Q&A drop in session regarding this tender will be held on 18/02/2026 at 13:00 GMT Please respond VIA In-Tend for invitation details The equipment is required for use at the HSE Buxton (SK17 9JN) test site

Key requirements

What the supplier must deliver

01

The PRS will be connected to

The PRS will be connected to a bulk hydrogen supply up to 500 barg.

02

The PRS should be able to control

The PRS should be able to control a flow of gaseous hydrogen at a set flow rate within the range 20.

03

The system should respond to a setpoint

The system should respond to a setpoint which is determined from an analogue signal sent to the pressure regulator.

04

If a dome regulator is used, HSE

If a dome regulator is used, HSE will provide and install a nitrogen supply to the regulator.

05

The PRS should be instrumented with pressure

The PRS should be instrumented with pressure and temperature upstream and downstream of the regulation, and a mass flow meter.

Derived from the notice text — always confirm against the original documents.

Buyer intelligence

Make the case to bid

Reveal who to approach at Health and Safety Executive, and generate a go-to-market strategy from their news, accounts and people.

Deep dive · beta

The full intelligence dossier

Our agent reads Health and Safety Executive’s accounts, hunts live signals, finds the people who decide — and hands you a bid strategy plus a go-to-market influence plan, including what your team should post this week. You approve every paid step.

Source & provenance
OCID
ocds-h6vhtk-064efc
Stage
tender · Open
Source
Find a Tender
Buyer ref
012868-2026
View the original notice on Find a Tender

Contains public sector information licensed under the Open Government Licence v3.0. Source data © Crown copyright.

Market context

Who wins this kind of work

The suppliers and buyers around this opportunity — drawn from official award data. Drag to orbit; click a node to explore.

Top suppliers & buyers in Laboratory & Precision Equipment

Scroll to explore the market network

Health and Safety Executive’s tender network

Assembling the network…