For the purchase of a system for non-invasive preclinical ultrasound imaging.
A single system is to be purchased that will permit visualisation of all of the following preclinical models: • Mouse embryos and zebrafish at resolutions down to 30 µm using an ultra-high frequency transducer (up to 71 MHz). • Mouse hearts and the vasculature in genetic and drug-induced models of disease at 30 µm resolution using a transducer of 30-40 MHz with a frame rate capable of imaging heart rates of up to 750 beats per minute.
ECG-gating is also required for 3D reconstruction of the heart. • Rat hearts and the vasculature in genetic and drug-induced models of disease (as detailed above for mice) using a transducer of ~29 MHz. • Mouse or rat brains (requiring a lower frequency transducer of ~22 MHz).
Additional capability is required for upgrading for imaging of pig hearts and the vasculature (requires low frequency transducers of 4-10 MHz) and for photoacoustic imaging.
The system must have the following provision: • Integrated physiology traces for small animals, including display of ECG, respiration waveform, and body temperature. • Capability for capturing B-mode and M-mode images, and for analysis of the images to provide data on cardiac and vascular function and dimensions in the above preclinical models (including strain and speckle-tracking). • Capability for Power Doppler, Pulsed-Wave Doppler, Pulsed-Wave tissue Doppler and colour Doppler for assessment of blood flow. • Capability for contrast imaging.
The University has published this VEAT notice and intends to award a contract to FUJIFILM Visualsonics Inc. following the expiry of 10 full calendar days after the expiry of this notice.
What the supplier must deliver
Mouse hearts and the vasculature in genetic
Mouse hearts and the vasculature in genetic and drug-induced models of disease at 30 µm resolution using a transducer of 30-40 MHz with a frame rate capable of imaging heart rates of up to 750 beats per minute.
The system must have the following provision
The system must have the following provision:.
Integrated physiology traces for small animals, including
Integrated physiology traces for small animals, including display of ECG, respiration waveform, and body temperature.
Capability for capturing B-mode and M-mode images
Capability for capturing B-mode and M-mode images, and for analysis of the images to provide data on cardiac and vascular function and dimensions in the above preclinical models (including strain and speckle-tracking).
Derived from the notice text — always confirm against the original documents.
Make the case to bid
Reveal who to approach at University Of Reading, and generate a go-to-market strategy from their news, accounts and people.
Ask me about this tender, the buyer, who wins their work, or whether you should bid.
- OCID
- ocds-h6vhtk-03749c
- Stage
- award · Awarded
- Source
- Find a Tender
- Buyer ref
- 028507-2022
Contains public sector information licensed under the Open Government Licence v3.0. Source data © Crown copyright.
Who wins this kind of work
The suppliers and buyers around this opportunity — drawn from official award data. Drag to orbit; click a node to explore.
Top suppliers & buyers in Laboratory & Precision Equipment
University Of Reading’s tender network
Assembling the network…