RFP QuestBeta
ClosedStage · tender

Stratton St Margaret Parish Council

Solar PV at Grange Leisure and Community Centre

ConstructionCPV 09310000
Value£50k
Deadline14 Nov 2025
Published13 Oct 2025
RegionNationwide
Timeline
Published 13 Oct 2025ClosedCloses 14 Nov 2025
Who to contact
info@strattonstmargaret.gov.uk

The procurement contact named on the official notice.

How to submit
Open the submissions portal

https://www.strattonstmargaret.gov.uk/tenders/ Submission by email to lee.wiseman@lexleisure.org.uk / joel.kirby@parkwood-leisure.co.uk

The submission route named on the official notice.

Contract value in context
£50ktotal contract value
median £600k
this tender£0£31.8m

This sits below the typical range for Petroleum, Fuel & Energy Products contracts — a smaller, more accessible award. Based on 3,437 valued Petroleum, Fuel & Energy Products tenders in our corpus.

Match for your company
Sign up free to see how well this tender matches your company — the score, the signals that align, and where the gaps are.
The brief

We are delighted to extend this invitation to tender for the design and installation of a roof mounted Solar PV system at Grange Leisure and Community Centre in Swindon.

The proposed project seeks to optimise the existing roof space, providing opportunity for electricity generation as part of our continued efforts to reduce our carbon footprint.

We invite experienced firms with a proven track record in Solar PV design and installation to participate in this tender process.

Your expertise and knowledge will play a fundamental role in the success of this major investment.

We look forward to receiving your proposals and collaborating on this project.

Who are we?

The Parkwood Group of companies are leading providers of support services to public and private sector clients.

The Group employs over 4,500 people throughout the UK providing services which include leisure management, green space management, healthcare, consultancy, and management of PFI projects.

Timescales Milestone Date Tender issue 13/10/2025 Tender deadline 14/11/2025 Tender review 17/11/2025 - 28/11/2025 Tender clarifications 28/11/2025 - 12/12/2025 Tender award 08/01/2026 Detailed design phase TBC Proposed construction start TBC Contact information If you have any questions with regards to this tender, or would like to arrange a site visit, please contact Lee Wiseman, the site manager via email - lee.wiseman@lexleisure.org.uk and Joel Kirby, Parkwood Leisure Energy and Sustainability Manager - joel.kirby@parkwood-leisure.co.uk 1.0 - Scope of works 1.1 - Existing site Information The solar PV system shall generate electricity from sunlight using photovoltaic panels.

The system shall consist of solar panels, mounting structures, inverters, electrical wiring, and associated components.

Address: Grange Leisure and Community Centre, Grange Dr, Swindon SN3 4JY The roof shown in red should be considered as part of this tender return.

Structural assessment should be carried out to assess additional loads and should be considered as part of the tender return.

Category Consideration Requirement Statutory consents Permitted development Required.

Subject to prior approval.

This will be submitted by the successful tenderer.

Planning permission Subject to prior approval.

This will be submitted by the successful tenderer.

Listed building consent Not required.

Conservation area No.

DNO G99 application must be submitted by the successful tenderer.

Any follow-up permissions, such as G100 and continued liaison with the DNO is the responsibility of the successful tenderer.

This includes witness testing which is to be performed at no impact to the operation of the facility.

Building regulations Contractor must conform to all relevant building regulations.

Environment Solar shading analysis Required.

Glare analysis Not required. *subject to prior approval conditions.

Roof compatibility Orientation Options available.

Structural assessment Required.

Roof defects / condition Not to our knowledge.

Materials Mix, to be confirmed on the site visit.

Age Warranty No.

Access Scaffold Budget Budget Constraints The project budget is £50,000+VAT.

This should be considered within tender returns.

Electrical infrastructure The contractor must ensure that the mains distribution has sufficient capacity to handle the additional load and that the wiring and components are in good condition.

It may be necessary to upgrade or make adjustments to the electrical infrastructure during the installation process.

Comments: To be reviewed during site visits.

Document checklist Provided by the client Document Appendix Building plans - showing plant / switch room location Site visit required.

Roof plan Appendix 1 Roof surface O&M Site visit required.

Electricity consumption data Appendix 4 Electrical schematics incl. metering strategy N Photographs of roof areas and switch rooms Appendix 3 Asbestos report Appendix 2 Compartmentation plans To be confirmed Fire Safety RC62 Checklist Appendix 5 Project outcomes Provided by the client Energy goals Comments (Y/N) Offset a certain percentage of energy consumption The scheme should be suited to the roof size, building load as designed by the contractor and budget highlighted above.

Completely energy independent No Contribute to environmental sustainability - Employer's requirements Solar panels The manufacturer, type and model of solar panel modules can be selected by the tenderer, subject to approval by PL.

The panels shall meet international standards for performance, durability, and safety.

Mounting structures The mounting structures shall securely support the solar panels on the desired installation location (e.g., ballasted - rooftop).

The structures shall be made of corrosion-resistant materials suitable for outdoor installation.

The design shall take into account wind loads, snow loads, and other environmental considerations specific to the installation location - in accordance with the structural information provided.

Inverters The solar PV system shall include grid-tied inverters capable of converting the DC power generated by the solar panels into AC power for use or export to the grid.

The required manufacturer for this scheme is Solis.

The inverters shall have a minimum efficiency of 93 - 96%.

The inverters shall meet relevant international safety standards and have built-in protection mechanisms against overvoltage, overcurrent, and other electrical faults.

Inverters should be located in well-ventilated spaces that do not exceed the optimum / recommended operating temperatures.

Inverters should always be mounted on fire-rated surfaces.

Inverters should be installed as close to the solar array as possible to reduce power losses.

Inverters should be protected from the elements, positioned away from direct sunlight, rain, snow, etc.

Electrical wiring and protection The system shall include appropriate electrical wiring to interconnect the solar panels, inverters, and other components.

The wiring shall be sized correctly to minimise losses and comply with local electrical codes and regulations.

Protection devices, such as surge protectors, circuit breakers, and disconnect switches, shall be installed as per applicable safety standards.

All cabling will be fully supported and secured in cable trays.

All cabling will be labelled accordingly, and be weather-proof when external.

Wiring diagram, providing the routes of cabling (including external cable runs) will be provided as part of the system O&Ms.

Batteries It is not anticipated that there will be a requirement for batteries for this project.

Monitoring and control The solar PV system shall incorporate a monitoring and control system to track system performance, energy production, and potential issues.

The monitoring system shall provide real-time data on energy generation, consumption, and system health through the Solis interface.

Installation and commissioning The solar PV system shall be installed by qualified personnel following industry best practices and local regulations.

A comprehensive commissioning process shall be conducted to ensure the system operates as intended and meets performance specifications.

All necessary permits and approvals shall be obtained before installation and commissioning.

Warranty and maintenance The solar panels, inverters, and other system components shall have a warranty period of: ● Solar PV panels - 20 years ● Solar PV - inverters - 10 years ○ Option for extended warranty required. ● Mounting system - 20 years The warranty shall cover defects in materials and workmanship and guarantee a minimum performance output over the warranty period.

A recommended maintenance plan shall be provided to ensure optimal performance and longevity of the system.

The contractor shall ensure that there's a nearby water connection to enable cleaning of the solar PV panels.

The contractor shall ensure that there's a nearby electrical connection to enable cleaning the solar PV panels.

Solar panel placement: panels should be accessible to clean and inspect without excessive leaning or specialist equipment.

Inverter placement: technicians should be able to reach the inverters without difficulty for routine inspections, repairs, or replacements if needed.

Always follow manufacturers instructions for specified distances between individual inverter units.

The design shall not restrict rainwater run-off from the existing roof structure.

Gulleys must be left exposed to enable roof cleaning / maintenance.

The contractor shall provide the employer a collateral warranty of 5 years.

The contractor will provide a comprehensive operational and maintenance manual, detailed drawings, schematics, handover training with the site team and 12-months of soft landing / servicing support (in the event of issues arising in accordance with the collateral warranty) and electrical compliance checks.

Access The contractor will provide all necessary access equipment to safely complete the installation, in accordance with relevant health and safety regulations.

H&S The contractor will comply with the Construction Design Management (CDM) Regulations 2015, adopting the role of Principal Contractor, and where also responsible for design, Principal Designer.

The scheme will be compliant with RC62 and a full RC62 checklist will be completed and submitted as part of the design and handover process.

This includes the installation of a fireman's switch and full integration at the fire panel.

A pre and post fire-risk assessment must be completed at design and handover of the scheme.

Contracts The contractor will enter into a JCT Minor Works Contract, or with Contractor's Design elements depending on the package.

Finances Contractor to carry out a detailed financial assessment including upfront cost, available incentives or rebates, potential energy savings, and return on investment.

Key requirements

What the supplier must deliver

01

The Parkwood Group of companies are leading

The Parkwood Group of companies are leading providers of support services to public and private sector clients.

02

The solar PV system shall generate electricity

The solar PV system shall generate electricity from sunlight using photovoltaic panels.

03

The system shall consist of solar panels

The system shall consist of solar panels, mounting structures, inverters, electrical wiring, and associated components.

04

The roof shown in red should

The roof shown in red should be considered as part of this tender return.

05

Structural assessment should be carried out

Structural assessment should be carried out to assess additional loads and should be considered as part of the tender return.

Derived from the notice text — always confirm against the original documents.

Buyer intelligence

Make the case to bid

Reveal who to approach at Stratton St Margaret Parish Council, and generate a go-to-market strategy from their news, accounts and people.

Deep dive · beta

The full intelligence dossier

Our agent reads Stratton St Margaret Parish Council’s accounts, hunts live signals, finds the people who decide — and hands you a bid strategy plus a go-to-market influence plan, including what your team should post this week. You approve every paid step.

Source & provenance
OCID
ocds-h6vhtk-05ae27
Stage
tender · Open
Source
Find a Tender
Buyer ref
064703-2025
View the original notice on Find a Tender

Contains public sector information licensed under the Open Government Licence v3.0. Source data © Crown copyright.

Market context

Who wins this kind of work

The suppliers and buyers around this opportunity — drawn from official award data. Drag to orbit; click a node to explore.

Top suppliers & buyers in Petroleum, Fuel & Energy Products

Scroll to explore the market network

Stratton St Margaret Parish Council’s tender network

Assembling the network…

Also open now

Similar open tenders

BSS26007 - Roofing and Solar Framework

Barcud Shared Services

Closes 14 Aug 2026Construction
£32.0mValue

2026 Liquefied Petroleum Gas(LPG)Tank for Devizes Training Centre

Dorset & Wiltshire Fire and Rescue Authority

Closes 31 Jul 2026Energy
Value not publishedValue